Sensor and measurement types.
Review the four current sensor configuration types and the measurements they supply. Choose the measurements your design needs while the study is in Preparing.
On this page
Collection and question delivery are separate. A measurement can support analysis even if it does not start a question; a scheduled or answer-dependent question can work without any sensor.
Current sensor configuration types
Beacon proximityRecord proximity to installed study beacons.
- Configuration
- Collection interval (5, 10, 15 or 20 minutes); beacon identifiers (UUID/major/minor); proximity and departure settings.
- Requirements and checks
- Requires deployed beacons, the correct identifiers, and phone permissions. Coordinate proximity settings with the team, then test in the actual spaces.
The distinct Beacon proximity fields replace the GPS settings in the illustrated arrival task. Review the collection interval, units and permissions for this measurement.
See the full beacon sensor form
GPS locationRecord phone location for place-based observations.
- Configuration
- Collection interval (5, 10, 15 or 20 minutes); movement threshold (0–10,000 meters); privacy setting.
- Requirements and checks
- Requires location permission and the intended background behavior. A collection interval is not a promise of an exact arrival-trigger latency.
The distinct GPS location fields replace the GPS settings in the illustrated arrival task. Review the collection interval, units and permissions for this measurement.
See the full gps sensor form
Bluetooth (BLE) proximityRecord proximity among participating devices.
- Configuration
- Collection interval (5, 10, 15 or 20 minutes); unseen-device timeout (300–3,600 seconds); privacy setting.
- Requirements and checks
- Requires compatible participating phones and Bluetooth permissions. Choose the privacy setting to match the approved design.
The distinct Bluetooth (BLE) proximity fields replace the GPS settings in the illustrated arrival task. Review the collection interval, units and permissions for this measurement.
See the full ble sensor form
Health ConnectCollect linked health-related measurements such as heart rate and step count.
- Configuration
- Collection interval (5, 10, 15 or 20 minutes); heart-rate and/or step-count selection. Select at least one.
- Requirements and checks
- Requires an available measurement source and health-data permission. Confirm the intended phone platform and source; the interface label alone does not establish that the same source is available on every device.
The distinct Health Connect fields replace the GPS settings in the illustrated arrival task. Review the collection interval, units and permissions for this measurement.
See the full health sensor form
Other integrations represented in the rule inventory
The rule definitions also include classic Bluetooth proximity, activity recognition and Empatica E4 wearable measurements. These are not additional entries in the current four-type sensor configuration list. Confirm the integration, supported devices and collection setup with the ODIN team before relying on them.
Forecasts are computed outputs, rather than a phone sensor. End-to-end forecaster registration currently requires coordination with the ODIN team; questions that respond to a configured forecast can be specified in the website UI.
Check the measurement before the trigger
- Confirm the intended participant devices, permissions and data source.
- Choose the collection interval and any privacy setting for the approved protocol.
- Check that measurements arrive under ordinary phone use.
- Then check the rule and any filters using that measurement.
Sampling intervals and the time allowed to answer a question are different settings. Do not compensate for missing measurements by repeatedly changing a question’s response window.
When checking a downloaded archive, use the sensor file schemas to find the measurement payload, observation time and upload time.